B16.34 wall thickness/ B16.5 flange hub diameter
1. Table 3-B gives valve body minimum wall thicknesses based on inside
diameter. I believe these values are based on a 30k min yield
material. Is this true?
2. For an 8" full bore 2500# valve,
B16.5 table F22 gives a hub diameter "x" of 12.00". With an 8" thru
bore, the wall thickness between the body and the flanges, due to the
"hub diameter" will be sub minimum (1.97" vs. required
2.83"). Increasing the "hub diameter" in order to meet the 16.34 wall
thickness requirement will interfere with nuts sitting on B16.5 dictated
bolt circle. What am I missing here?
1. See B16.34 Appendix B for method used for establishing P-T ratings
2.
the 8" class 2500 full port valve is 5.75" in diameter not 8" (B16.34
appendix A). You won't find a 8" class 2500 valve with an 8" thru
bore. (5.75 + 2.06*2 = 9.87")
the valve vendor has stated the thru diameter is 8"? that would be
surprising API 6D (which has the largest port requirements I'm aware of)
only requires 7.05" (179 mm)
The valve can have a larger
diameter than 5.75" and still meet B16.34 (it could have a smaller one
for that matter) since the port diameter appendix is non-mandatory.
Generally though the port diameter of the valve will be in accordance
with API 600 (if this is a gate, globe or swing check valve) which
requires 5.75".
Also for gate, globe, and checks most companies
are now designing valves to API 600 wall as well which in this case
would be 62mm (2.44")
I apologize for some reason I thought I read gate valve in the first
post. I do not have a lot of experience with ball valves and the
standards that govern their design. You may want to look at API 608.
But
you are correct if the valve states it meets B16.34 then it would need
to meet the wall thickness requirements in Table 3-B. If it doesn't then
it doesn't meet B16.34
MORE NEWS
2011-02-16