Electric fluorine lined adjustable butterfly valve
manufacturer: Shanghai MeiYan Yi Pump & Valve Co., Ltd.
Eml: sales@1bengfa.com
Tel: +86 (21) 5640 2009
Mob: +86 138 1691 3072(WeChat Same Account)
product drawing
Electric fluorine lined adjustable butterfly valves
features
DYH971F46 electric fluorine-lined regulative butterfly valve has switch and intelligent type,equipped with YHR actuators, input control signal (4-20mADC or 1-5VDC) and single phase power can control operation, has the strong function, small volume, light, reliable in performance, simple mating, complete ability, especially suitable for large circulation in medium is sticky, including particle, fiber properties. This valve is widely used in food, environmental protection, light industry, the petroleum, the papermaking, the chemical industry, the teaching and the scientific research equipment, electric power industries and other industrial automatic control system.
structure
Electric fluorine lined adjustable butterfly valve constructral diagram(pic1)
Electric fluorine lined adjustable butterfly valve constructral diagram(pic2)
technical parameters and performance indicators
body
DN:50~400mm
PN:PN1.0,1.6,2.5MPa
connection: flange according to JB/T78-59 JB79-59 wafer flange connection
material:HT200 ZG25I ZG1Cr18Ni9
ZG0Cr17Ni12Mo2 PTFE lined
medium temperature:normal temperature:-20~+200 radiating type:-40~+450
internal components
core type: disc
flow characteristic: linear or equal percentage
material:HT200 ZG25I 1Cr18Ni9Ti lined rubber and PTFE
actuators
Type: can choose PS series, 3810, DTR series electronic angle stroke actuators.
Technical parameters and properties: please refer to the corresponding actuator and valve locator instruction.
specification parameters table
DN | 50 | 65 | 80 | 100 | 125 | 150 | 200 | 250 | 300 | 350 | 400 |
flow coefficient(Kv) | 110 | 180 | 232 8 | 368 | 656 | 735 | 1240 | 2025 | 2712 | 3875 | 503 |
acting scope | 0-90o | ||||||||||
allowed pressure differential △P | Less than PN(1.6MPa) | ||||||||||
leakage Q | according to GB/T4213-92,is 10-4% of Kv | ||||||||||
environmental temperature ℃ | -20~60oC | ||||||||||
intrinsic error | ±2.5% | ||||||||||
back differential | ±2.5% | ||||||||||
dead zone | 1% | ||||||||||
adjustable scope | 250:1 350:1 | ||||||||||
equipped actuator | YHR—05 10PSQ101381RSA-05 | YHR— 20PSQ201381RSC-30 | YHR-40PSQ501381RSC-50 | YHR-60PSQ701 |
dimensions
DN | L | H | H1 | D2 | Z-фd | D1 | L1 | L2 |
50 | 43 | 452 | 80/112 | 120/125 | 4-18 | 165 | 208 | 120 |
65 | 46 | 475 | 88/115 | 136/145 | 4-18 | 185 | 208 | 120 |
80 | 46/49 | 516 | 96/120 | 160 | 8-18 | 200 | 208 | 120 |
100 | 52/56 | 551 | 115/140 | 185 | 8-18 | 220 | 208 | 120 |
125 | 56/64 | 566 | 128/170 | 210 | 8-18 | 220 | 208 | 120 |
150 | 56/70 | 606 | 140/180 | 240 | 8-22 | 285 | 256 | 156 |
200 | 60/71 | 731 | 175/210 | 295 | 8-22 | 340 | 256 | 156 |
250 | 68/76 | 778 | 202/240 | 355 | 12-22 | 395/405 | 256 | 156 |
300 | 78/83 | 830 | 242/290 | 410 | 12-22 | 445/460 | 256 | 156 |
350 | 78/92 | 996 | 266/320 | 470 | 16-22 | 505/520 | 346 | 156 |
400 | 102 | 1058 | 298/350 | 515/525 | 16-26 | 565/580 | 346 | 156 |
external dimensions
DN | L | H | H1 | D2 | D1 | Z-фd | L1 | L2 |
50 | 108 | 539 | 825/112 | 165 | 125 | 4-18 | 208 | 120 |
65 | 112 | 554 | 925/115 | 185 | 145 | 4-18 | 208 | 120 |
80 | 114 | 569 | 100/120 | 200 | 160 | 8-18 | 208 | 120 |
100 | 127 | 614 | 110/138 | 220 | 180 | 8-18 | 208 | 120 |
125 | 140 | 649 | 125/164 | 250 | 210 | 8-18 | 208 | 120 |
150 | 140 | 725 | 1425/175 | 285 | 240 | 8-22 | 256 | 156 |
200 | 152 | 835 | 170/208 | 340 | 295 | 8-22/2-22 | 256 | 156 |
250 | 165 | 890 | 1925/243 | 395/405 | 350 | 12-22/12-26 | 256 | 156 |
300 | 178 | 995 | 2225/283 | 445/460 | 400 | 12-22/12-26 | 256 | 156 |
350 | 190 | 1155 | 2525/310 | 505/520 | 460 | 16-22/16-26 | 346 | 156 |
400 | 216 | 1225 | 2825/340 | 565/580 | 515 | 16-26/16-30 | 346 | 156 |
ordering notice
1. Product model and name 2. Nominal diameter DN (mm) (3) nominal pressure (4) flow characteristics 5. body material 6. rated flow coefficient 7. medium type and scope of temperature 8. pressure around valve (pressure differential) 9. The power supply voltage and control signal 10. Other special requirements